Dietrich Aura
A dental porcelain furnace equipped with automatic calibration (ARK), precise temperature control up to 1250°C and a smart vacuum system.

Screen interface
Real images from the 7 inch touchscreen. Every setting on large, readable cards.

A furnace that protects itself
With the latest software updates Aura checks itself more to protect your work. All of it reached existing furnaces through an online update.
Checks itself at start-up
At every start, before heating, the furnace briefly tests its temperature sensor and heater. If something is wrong, it tells you before any work goes in.
Leak test
The lid seal and vacuum hoses are measured in about 3 minutes and the result is shown clearly. It starts with one touch from the preset programs screen.
Vacuum pump monitoring
Aura watches how the pump runs in every firing. If the pump struggles, it protects the motor, tries again and lets you know on the screen and on your phone.
No heating without vacuum
If vacuum cannot be built, it waits without raising the temperature, so your work is never fired without vacuum.
Resume after a power cut
After a short power cut, if the lid is closed and the temperature allows, the firing continues where it stopped.
Voice setup guide
On first start it introduces the furnace step by step with voice narration. Turkish and English.
Number pad editing
Tap a program value and type it directly on the number pad. Holding plus or minus speeds up in steps of 1, 5 and 10.
Firing curve
The temperature, target and vacuum curve of recent firings is shown in the web portal and on your phone.
System info and latest checks
Software versions and the furnace's own latest checks on one page, so service calls are shorter.
Smart features
From preset programs to remote management — the functions a laboratory uses every day.
100 preset programs
Prepared according to the firing recommendations of six leading ceramic manufacturers. Drying, cooling and lift movements are defined; you don't need to write a program from scratch.
1000 personal programs
Your own programs are stored on the furnace and backed up to the cloud automatically. Even if the furnace changes, your programs move to the new one.
Remote program editing
Edit programs from the web portal, the desktop app or your phone and send them to the furnace. Bulk changes can be undone within 7 days.
Voice notifications
Program started, completed, vacuum leak… 27 voice announcements; you choose a female or male voice. The announcements are in Turkish.
Live monitoring and night mode
Temperature, vacuum, stage and remaining time on your phone; you get a notification when a firing finishes or a fault occurs, even with the app closed. Turn on night mode instantly or at a time you set every day.
Starts with your last program
When the furnace is switched on, the program you used last is already selected; you start the day's first firing with a single tap.
Signed remote updates
The display and control boards are updated with a single confirmation. Software whose digital signature cannot be verified is never installed on the furnace.
Fault logging and diagnosis
Every fault is recorded with its code. Des AI suggests a step-by-step solution based on Dietrich's technical documents.
1300 °C absolute safety limit
The control board never exceeds this temperature under any circumstances. In a critical fault the heater switches off and the event is recorded.
Technical specifications
Designed around the real needs of the laboratory
Device screen
A clear, direct interface. The furnace's own touchscreen shows the information a technician needs without clutter: current temperature, active program, vacuum status and connection status are always visible.
- Current temperature
- 37°C
- Program
- DENTİM 1
- Target temperature
- 900°C
- Vacuum level
- 96.0 kPa
Sample values. The connection status is also always shown on the screen.
What's inside?
Two mutually independent boards, field-tested hardware.
Processing and Control
- Display Board
- Touch interface and connectivity
- Control Board
- Heating, vacuum and lift control
- Architecture
- The two boards work independently of each other
- Settings
- Calibration and settings are stored permanently
Measurement
- Temperature
- Type R thermocouple (standard)
- Sensor Accuracy
- ±0.1°C
- Vacuum
- Precision pressure sensor
- Display
- 7" full touchscreen
Heating and Motion
- Heater
- Quartz heating element
- Lift
- Protected motor, stops automatically when jammed
- Updates
- Both boards are updated wirelessly (signed software)
Safety Architecture
- Hardware Lock
- The device serial number is written to the board
- Calibration Security
- 5-digit code specific to the serial number, generated in DES
- Electrical Protection
- Relay interference protection
- Notifications
- Voice announcements and audible alerts in critical situations
- Absolute Limit
- The control board never exceeds 1300 °C under any circumstances
How does ARK work?
It calibrates itself in the field, without a technician.
- 01
10 Firings Are Completed
The counter triggers; as soon as the next firing ends, the calibration cycle starts automatically.
- 02
The Furnace Asks
"Are you satisfied with this firing?" A yes locks the offset; a no moves on to the next step.
- 03
+1°C Offset Is Added
Until a satisfied answer is received, the offset is increased by 1°C with each negative answer, and the question is asked again at the next firing.
- 04
Resets When the Heating Element Is Replaced
When the service counter is reset, the offset automatically returns to 0°C and the cycle starts over for the new heating element.