Dental Furnaces

Dietrich Aura

A dental porcelain furnace equipped with automatic calibration (ARK), precise temperature control up to 1250°C and a smart vacuum system.

Dietrich Aura porcelain furnace
1250°C precise controlType R thermocouple, 19-bit measurement
ARK self-calibrationNo technician intervention required
Touchscreen7" full touch, Turkish and English interface

Screen interface

Real images from the 7 inch touchscreen. Every setting on large, readable cards.

Home screen
Current temperature, a summary of the selected program and one-touch start.

A furnace that protects itself

With the latest software updates Aura checks itself more to protect your work. All of it reached existing furnaces through an online update.

Checks itself at start-up

At every start, before heating, the furnace briefly tests its temperature sensor and heater. If something is wrong, it tells you before any work goes in.

Leak test

The lid seal and vacuum hoses are measured in about 3 minutes and the result is shown clearly. It starts with one touch from the preset programs screen.

Vacuum pump monitoring

Aura watches how the pump runs in every firing. If the pump struggles, it protects the motor, tries again and lets you know on the screen and on your phone.

No heating without vacuum

If vacuum cannot be built, it waits without raising the temperature, so your work is never fired without vacuum.

Resume after a power cut

After a short power cut, if the lid is closed and the temperature allows, the firing continues where it stopped.

Voice setup guide

On first start it introduces the furnace step by step with voice narration. Turkish and English.

Number pad editing

Tap a program value and type it directly on the number pad. Holding plus or minus speeds up in steps of 1, 5 and 10.

Firing curve

The temperature, target and vacuum curve of recent firings is shown in the web portal and on your phone.

System info and latest checks

Software versions and the furnace's own latest checks on one page, so service calls are shorter.

Smart features

From preset programs to remote management — the functions a laboratory uses every day.

100 preset programs

Prepared according to the firing recommendations of six leading ceramic manufacturers. Drying, cooling and lift movements are defined; you don't need to write a program from scratch.

1000 personal programs

Your own programs are stored on the furnace and backed up to the cloud automatically. Even if the furnace changes, your programs move to the new one.

Remote program editing

Edit programs from the web portal, the desktop app or your phone and send them to the furnace. Bulk changes can be undone within 7 days.

Voice notifications

Program started, completed, vacuum leak… 27 voice announcements; you choose a female or male voice. The announcements are in Turkish.

Live monitoring and night mode

Temperature, vacuum, stage and remaining time on your phone; you get a notification when a firing finishes or a fault occurs, even with the app closed. Turn on night mode instantly or at a time you set every day.

Starts with your last program

When the furnace is switched on, the program you used last is already selected; you start the day's first firing with a single tap.

Signed remote updates

The display and control boards are updated with a single confirmation. Software whose digital signature cannot be verified is never installed on the furnace.

Fault logging and diagnosis

Every fault is recorded with its code. Des AI suggests a step-by-step solution based on Dietrich's technical documents.

1300 °C absolute safety limit

The control board never exceeds this temperature under any circumstances. In a critical fault the heater switches off and the event is recorded.

Technical specifications

Temperature System
Program TemperatureUp to 1250 °C
Measurement Resolution19-bit, 0.0078 °C steps
LinearityMax. 0.15% of full scale; hardware linearization specific to the thermocouple
Noise Suppression50/60 Hz mains filter, broken thermocouple detection
ThermocoupleR tipi (standart)
ControlPID algorithm + automatic calibration (ARK)
SecurityAutomatic lock if the thermocouple breaks
Vacuum System
Vacuum PowerPrecise measurement down to -100 kPa
Stop When ReachedThe pump stops when the target pressure is reached; economical, low energy
Fully ActiveThe pump runs continuously; maximum, constant suction
AutomaticStarts in Stop When Reached mode; switches to Fully Active by itself if a pressure loss is detected
Pump CompatibilityWorks with economical vacuum pumps
Safety Architecture
Independent BoardsThe Display Board and Control Board work separately
Uninterrupted FiringThe firing completes safely even if the screen freezes
Lift ProtectionAutomatic power cut on jamming
Part LockEncrypted calibration code when critical parts are replaced
Interface and Connectivity
Display7" full touchscreen, Turkish interface
Program Memory1000 personal programs and 100 preset programs
Lift ControlProgram-based slot positions
ConnectivityCloud connection via WiFi, signed wireless updates
Remote ManagementWeb portal, desktop and mobile app

Designed around the real needs of the laboratory

ARK: Automatic Heating-Element CalibrationThe furnace calibrates itself; no technician intervention required.
Precise control up to 1250°C19-bit measurement, 0.0078 °C resolution and hardware linearization; adaptive heating that predicts heat 25 seconds ahead.
Uninterrupted firing guaranteeThe Display Board and Control Board work separately; the firing completes safely even if the screen freezes.
Smart vacuum systemStop When Reached, Fully Active and Automatic modes. If it detects a leak during firing, it gives an audible alert at the end of the program and suggests switching all programs to Fully Active mode to protect the motor.

Device screen

A clear, direct interface. The furnace's own touchscreen shows the information a technician needs without clutter: current temperature, active program, vacuum status and connection status are always visible.

Current temperature
37°C
Program
DENTİM 1
Target temperature
900°C
Vacuum level
96.0 kPa

Sample values. The connection status is also always shown on the screen.

What's inside?

Two mutually independent boards, field-tested hardware.

Processing and Control

Display Board
Touch interface and connectivity
Control Board
Heating, vacuum and lift control
Architecture
The two boards work independently of each other
Settings
Calibration and settings are stored permanently

Measurement

Temperature
Type R thermocouple (standard)
Sensor Accuracy
±0.1°C
Vacuum
Precision pressure sensor
Display
7" full touchscreen

Heating and Motion

Heater
Quartz heating element
Lift
Protected motor, stops automatically when jammed
Updates
Both boards are updated wirelessly (signed software)

Safety Architecture

Hardware Lock
The device serial number is written to the board
Calibration Security
5-digit code specific to the serial number, generated in DES
Electrical Protection
Relay interference protection
Notifications
Voice announcements and audible alerts in critical situations
Absolute Limit
The control board never exceeds 1300 °C under any circumstances

How does ARK work?

It calibrates itself in the field, without a technician.

  1. 01

    10 Firings Are Completed

    The counter triggers; as soon as the next firing ends, the calibration cycle starts automatically.

  2. 02

    The Furnace Asks

    "Are you satisfied with this firing?" A yes locks the offset; a no moves on to the next step.

  3. 03

    +1°C Offset Is Added

    Until a satisfied answer is received, the offset is increased by 1°C with each negative answer, and the question is asked again at the next firing.

  4. 04

    Resets When the Heating Element Is Replaced

    When the service counter is reset, the offset automatically returns to 0°C and the cycle starts over for the new heating element.

Contact Us

Let's talk about Dietrich Aura

Write to us for a quote, technical questions or distribution.

Your personal data is processed to respond to your request. KVKK Privacy Notice